It’s a a sterilizer that uses the dual effects of microwave and high-pressure steam to disinfect medical waste.
Treatment capacity appr. 2kg/hr, based on an average density of medical waste at 0.1kg/l ~0.15kg/l.
PARAMETERS:
It’s a sterilizer that uses the dual effects of microwave and high-pressure steam to disinfect medical waste.
Treatment capacity appr. 2kg/hr, based on an average density of medical waste at 0.1kg/l ~0.15kg/l.
Technical Principle
Microwave disinfection equipment for medical waste is a device that uses the dual effects of microwave and high-pressure steam to disinfect medical waste. The equipment first introduces high-pressure saturated steam into the high-pressure disinfection chamber of medical waste, while starting a microwave generator. It uses the thermal effect of microwave to heat the high-pressure disinfection chamber to maintain temperature and prevent steam condensation. It is sterilized by the sensitivity of bacteria to temperature. In addition, microwave has a non-thermal effect, Non thermal effect refers to other microbial killing effects besides thermal effect, which is a unique effect of microwave sterilization. The heating and warming process of the equipment is also a disinfection process. After the disinfection room reaches 135 ℃ or above, it is kept for another 5 minutes to complete the disinfection.
PARAMETER | SPECIFICATIONS |
Dimensions of the main unit body | 634mm*503mm*749mm |
Overall weight | 110kg |
Treatment type | High temperature Microwave disinfection |
Type of process | Semi-automatic process |
Option form | Simple button operation |
Sterilization temperature | ≥ 135℃ |
Pressure | ≥ 0.33MPa |
Sterilization cycle | ≥ 30 minutes |
Installed power | 3.5 Kw |
Utility Requirements | Electricity: 220V |
Treatment capacity * | 17L/cycle, or appr. 2 kg/hr (±10%) |
Manpower requirements | No specialized operator / 1 operator |
Exhaust gas treatment system | Contain |
Disinfection section material | 304 stainless steel |
Microwave frequency | 2450 +/- 50 MHz |
Microwave generator power | 1.25kW |
Treatment effect | 6 log 10. The treatment effect test uses Bacillus subtilis var. niger spore (ATCC 9372) as biological indicator, with killing logarithm value ≥ 6.00. |
A printer integrated with the machine that can trace cycle data, such as hospital name/operator name/cycle time/weight/cycle status. |
The processing scope of the equipment includes infectious, injurious, and pathological (excluding human limbs and organs) waste in the category of medical waste.
Do not put sealed containers into the equipment.
Structural characteristics of the unit
High pressure steam and microwave combination disinfection, the disinfection process only takes 5 minutes, high disinfection efficiency, energy saving;
Using a water cooled microwave generator, the cooling medium is antifreeze, with a long service life;
The door of the microwave disinfection equipment adopts a conductive sealing strip sealing structure and is equipped with an interlocking system to prevent microwave leakage;
The disinfection chamber is made of 304 stainless steel, it is durable.
Equipped with an exhaust gas treatment device, including a high-efficiency filter and an activated carbon filter, the high-efficiency filter is used to treat microorganisms contained in the exhaust gas, with a filter particle diameter of 0.2 μ m. It can filter out almost all microorganisms, and activated carbon filters are used for deodorization.
Get A Free Quote
Tel:
+86-370-5068088Email:
[email protected]Mob/Wechat/Whatsapp:
008619711230880Subscribe to our mailing list:
PDF Request