MDU-10B PRO+

MDU-10BS is LiYing’s 2024 New design & tec Medical Waste Treatment System including feeding, shredding, disinfection, discharging, and exhaust dedusting systems.

Specifications:

  • Treatment capacity: 1000kg/h (±10%)
  • Dimensions (L*W*H): 11500mm*2720mm*3200mm
  • Overall weight: 13500kg
  • Required space (L*W*H): 15000*5000*5600mm

    MDU-10BS

    MDU-10BS Medical waste steam microwave Disinfection Equipment with 2024 brand new upgraded design, materials and technology, is used for the harmless disposal of medical waste. The scope of disposal is medical waste that is classified as infectious, traumatic, and pathological waste. It is also used in epidemics to dispose of sick and dead poultry.

    Click below to watch the MDU video

    Liying medical waste microwave disinfection equipment MDU-10BS

    Microwave disinfection unit for medical waste Model MDU-10BS

    • MDU-10BS is an integration system including feeding, shredding, disinfection, discharging, and exhaust dedusting systems.
    • Energy saving: half the cost of autoclaves. Effective: 99.9999% sterilizing effect.
    • 1,000kg/h or 9,000l/h treatment capacity, based on an average density of medical waste at 0.1kg/l ~0.15kg/l.
    • Can serve cities with a population of 3 million well. You can choose it if you are an organization that provides medical waste collection and centralized disposal services to local hospitals, clinics, etc. in cities or regions with a population of about 3 million.

    Specifications

    Equipment Model No.MDU-10BS
    Treatment Capacity1,000kg/h
    Dimensions (LWH)11,500mm*2,720mm*3,200mm
    Overall weight13,500kg
    Required space (LWH)15,000mm*5,000mm*5,600mm
    Installed Power360KW (108KW steam generator included)

    Process

    -The infectious material is temporarily held in a waste container(s) which in turn, are emptied into an pre storage hopper via a charging system which is located at the front of the MDU.
    -The infectious waste is fed to the shredding system by a feed arm where it is shredded.
    -The shredded material is conveyed through a microwave section and temperature holding section, respectively for disinfection, with microwave of 2450MHz (±50MHz), temperature ≥95℃, with over 45minutes.
    -The disinfected and unrecognizable (sharps) waste is then discharged into large waste containers (or compaction units) by the discharging screw conveyor.
    -From there the material can be transported to a local municipal landfill for disposal or to a refuse recycling plant.

    What does the Microwave Disinfection Unit (MDU) for Medical Waste do to bacteria? and How does the Medical Waste Microwave Disinfection Unit (MDU) perform microwave sterilization?

    Microwave disinfection is the result of microwave thermal effect and biological effect, which can make microwave energy and bacteria directly interact, rapid sterilization.

    The thermal effect of microwave energy: Under certain intensity microwave field, the bacteria will be due to the absorption of polarized molecules can increase the temperature of microwave, so that the protein deformation, loss of biological activity. The thermal effect of microwave mainly plays the role of rapid temperature sterilization.

    Non-thermal effects of microwave energy: High-frequency electric fields change the polarized molecular structure, resulting in the loss of vitality or death of proteins and physiologically active substances in the microbes, and the special effects of conventional physical sterilization in the sterilization

    Applicable Range

    • Blood and Blood Products
    • Dialysis Waste
    • Animal Tissues, Body Parts, and Carcasses
    • Human Tissues, Body Parts, and Limbs
    • Biological and Non-Hazardous Pharmaceutical
    • Needles, Syringes, and other Sharps
    • Research Waste 
    • Laboratory Specimens
    • Surgery Waste
    • Pathology and Histology Samples
    • Aids and Hepatitis Waste
    • Isolation Waste
    • Cultures and Slides
    • Intravenous Bags, Blood Bags, and Associated Tubing
    • Animal Bedding
    • Packaging Materials
    • Gloves, and Gowns Associated with Waste Collection
    • Trace Chemotherapy/anti- neo plastic waste

    Equipment Technical Advantages

    MDU series products are designed as an automatic operation system with minimal operator operations, with the following characteristics:

    01
    Energy saving

    Microwave heating is uniform, no energy loss, high energy, strong penetration into the object, instantaneous penetration into the object, good energy-saving effect, take the model with a daily processing capacity of 5T/d as an example, installed power Only 117 kilowatts.

    02
    Efficient energy

    Low acting temperature, slow heat dissipation: when microwave and ordinary heating disinfect the same amount of waste, microwave disinfection will require a significantly lower temperature than ordinary heating, reducing heat emissions. Microwave sterilised waste is non-toxic, non-residual and lightly damaged.

    03
    Absolute sterilization and disinfection

    Microwave can effectively sterilize all materials on all organisms with no select. It has a broad spectrum of disinfection bacteria and can kill various microorganisms and pathogens.

    04
    Spatial convenience

    Microwave disinfection requires a small equipment functioning area, doesn't cause high temperatures in the surrounding environment, it's clean and hygienic.

    05
    Environmentally friendly

    No acid gases, dioxins or other pollutants are produced.

    The equipment has a high degree of automation, and only one person is required to operate a complete set of equipment, saving labor costs.

    Low energy consumption, the whole set of equipment only needs electric drive, taking 5t per day as an example, the total installed power is only 117 kilowatts.

    The medical waste treatment method is flexible. When there is medical waste to be processed at any time, the equipment can be turned off after the treatment is completed, which minimizes energy loss and personnel wages and saves treatment costs.

    There are two types of microwave disinfection equipment: fixed and mobile.

    Technical Compare

    Compare technologies

    LiYing Technology

    Autoclave

    Autoclave with a shedder

    Incinerator

     

    (Microwave)

    (Hot steam)

    (Hot steam)

    (Incineration)

    Continuous process

    X

    X

    X

    Integral shredding

    X

    X

    Unrecognisable waste

    X

    Volume of waste reduction

    X

    Mass of waste reduction

    X

    X

    Installation requirements

    Low

    High

    High

    High

    Complexity of the installation

    Low

    Intermediate

    Intermediate

    High

    On-site installable

    X

    Technical recognition

    High

    Intermediate

    High

    Low

    Level of sterelization

    High

    Intermediate

    High

    High

    Odours

    Low

    High

    Intermediate

    Intermediate

    Noise

    Low

    Intermediate

    Intermediate

    High

    Treatment of pathological and anatomical waste

    X

    Cost

    ROI

    High

    Low

    Low

    Low

    Investment costs

    Intermediate

    Low

    Intermediate

    High

    Operating costs

    Low

    High

    High

    High

    Maintenance costs

    Low

    High

    High

    High

    Labour costs

    Low

    High

    High

    High

    Environment

    Impacts on the environment

    Low

    Intermediate

    Intermediate

    High

    Treated waste recyclable

    X

    X

    X

    No contaminated rejection (such as water, steam)

    X

    X

    X

    Security

    No risk related to pressurized vessel

    X

    X

    X

    Risk for workforce/personnel health

    No risk of toxic contaminants released into the air or the treated waste

    Intermediate

    Intermediate

    High

    Get A Free Quote

    *
    *

    Related Products

    Related Cases

    WHAT CAN WE DO FOR YOU?

    *
    *

    Whatsapp

    8619711230880

    Contact

    Wechat

    Email

    [email protected]

    PDF Request

    *
    *