Medical Waste Disinfection Equipment SSE-Series

The MDU-SSE series equipment is a treatment process that utilizes high-temperature steam to disinfect medical waste; The process of steam treatment followed by crushing treatment is adopted, including process units such as “feeding, pre vacuum, high-temperature steam treatment, drying, discharge, and shredding”.

PARAMETERS:

  • Processing capacity: 25kg/cycle,   15kg/cycle
  • Disinfection Temperature: 134°C~138°C
  • Working Pressure: -0.09~0.24MPa
  • Disinfection Cycle: 30min

    Introduction

    The MDU-SSE series equipment is a treatment process that utilizes high-temperature steam to disinfect medical waste; The process of steam treatment followed by crushing treatment is adopted, including process units such as "feeding, pre vacuum, high-temperature steam treatment, drying, discharge, and shredding".

    It can service well to some large scale or medium scale hospitals, clinics, or any other healthcare centers, Customs epidemic prevention department, etc.

    Parameters

    Parameters
    ModelMDU-25GMDU-15G
    Processing capacity25kg/cycle,50kg/hr15kg/cycle,30kg/hr
    Power60Kw36Kw
    Dimensions (L*W*H)556cm*202cm*200cm430cm*180cm*175cm
    Disinfection effectlog5(Bacillus subtilis var. niger, ATCC9372)
    Power supplyThree phase five wire AC380V
    Working Pressure:-0.09~0.24MPa
    Disinfection temperature134℃~138℃
    Disinfection Cycle30min
    Weight6.5t3.5t

    Technical principle and characteristics:.

    The principle of the pressure steam sterilization process is to penetrate the pressure steam into the inside of the object. To coagulate, denature and kill microbial proteins. The treated medical waste is sent to sanitary landfills or incinerated. This method is also applicable to the disinfection of contaminated work clothes, syringes, dressings, microbial media, etc.

    Process

    The treatment process of medical waste includes medical waste, feeding,high-temperature steam sterilization disposal center ,Drying and Shredding,Discharge, health landfill.

    1. Feeding, the operator loads the medical waste into the hopper and then enters the automatic disinfection process.
    2. Steam sterilization, in this process, a preset pressure and temperature are first achieved through a heating procedure for disinfection.In the heat preservation stage, the waste is kept above the preset temperature and maintained for sufficient time to ensure disinfection. Steam is discharged through a pressure relief procedure.
    3. Drying and Shredding, Through the drying process, part of the water is removed from the waste to ensure that the waste reaches a completely sterile state. After treatment, the medical waste should be decontaminated and unrecognizable.
    4. Post-treatment, the completion of these procedures will ensure that clinical waste is thoroughly disinfected, and the waste gas generated during the disinfection process is collected by negative pressure fans and processed by the waste gas treatment system to protect the environment and public health and safety.
    5. Discharge, the disinfected and unrecognizable (sharps) waste is then discharged into large waste containers (or compaction units) by the discharging screw conveyor. From there the material can be transported to a local municipal landfill for disposal or to a refuse recycling plant.

    Applicable Range

    • Blood and Blood Products
    • Dialysis Waste
    • Animal Tissues, Body Parts, and Carcasses
    • Human Tissues, Body Parts, and Limbs
    • Biological and Non-Hazardous Pharmaceutical
    • Needles, Syringes, and other Sharps
    • Research Waste 
    • Laboratory Specimens
    • Surgery Waste
    • Pathology and Histology Samples
    • Aids and Hepatitis Waste
    • Isolation Waste
    • Cultures and Slides
    • Intravenous Bags, Blood Bags, and Associated Tubing
    • Animal Bedding
    • Packaging Materials
    • Gloves, and Gowns Associated with Waste Collection
    • Trace Chemotherapy/anti- neo plastic waste

    Equipment Advantages

    Easy transportation and installation with an integrated design.

    High degree of automation, single person operation, after the medical waste being poured into the hopper, the equipment automatically completes whole procedures of medical waste treatment

    Low water content in the treated medical waste, because of a vacuum drying technology.